{"id":23136,"date":"2025-12-15T03:49:49","date_gmt":"2025-12-15T03:49:49","guid":{"rendered":"https:\/\/esmte.com\/?post_type=product&#038;p=23136"},"modified":"2025-12-15T03:49:49","modified_gmt":"2025-12-15T03:49:49","slug":"smt-nozzle-cleaning-machine-ync-36","status":"publish","type":"product","link":"https:\/\/esmte.com\/vi\/products\/smt-nozzle-cleaning-machine-ync-36\/","title":{"rendered":"M\u00e1y l\u00e0m s\u1ea1ch v\u00f2i phun SMT YNC-36"},"content":{"rendered":"<h2>Gi\u1edbi thi\u1ec7u<\/h2>\n<p data-start=\"214\" data-end=\"625\">C\u00e1i <strong data-start=\"218\" data-end=\"256\">M\u00e1y l\u00e0m s\u1ea1ch v\u00f2i phun SMT YNC-36<\/strong> is a dedicated maintenance system developed to ensure consistent performance of SMT pick-and-place nozzles in high-precision electronic assembly lines. By effectively removing solder paste residues, flux build-up, dust, and micro-particles, the YNC-36 helps restore nozzle suction efficiency and placement accuracy, which are critical factors in modern SMT production.<\/p>\n<p data-start=\"627\" data-end=\"1046\">Designed to meet the strict quality requirements of <strong data-start=\"679\" data-end=\"716\">medical electronics manufacturing<\/strong>, the YNC-36 supports stable and repeatable assembly processes for sensitive components such as ICs, sensors, and miniature connectors. Clean nozzles reduce the risk of component misplacement, dropped parts, and alignment errors, directly contributing to lower defect rates and higher production reliability in medical PCBA lines.<\/p>\n<p data-start=\"1048\" data-end=\"1460\">C\u00e1i <strong data-start=\"177\" data-end=\"215\">M\u00e1y l\u00e0m s\u1ea1ch v\u00f2i phun SMT YNC-36<\/strong> features an automated cleaning process that minimizes manual intervention and operator dependency. Compared with traditional manual cleaning methods, the machine delivers uniform and controlled cleaning results while preventing mechanical damage to nozzles. This not only improves maintenance efficiency but also extends nozzle service life, reducing replacement frequency and overall operating costs.<\/p>\n<p data-start=\"1462\" data-end=\"1846\">In addition, the machine is suitable for integration into cleanroom or controlled manufacturing environments, supporting contamination control and audit-ready production conditions. Its compact design allows flexible placement near SMT lines, enabling quick nozzle turnaround and fast response to production changeovers commonly required in high-mix medical electronics manufacturing.<\/p>\n<p data-start=\"1848\" data-end=\"2130\">Nh\u00ecn chung, <strong data-start=\"1861\" data-end=\"1899\">M\u00e1y l\u00e0m s\u1ea1ch v\u00f2i phun SMT YNC-36<\/strong> is an essential support system for medical electronics factories seeking to enhance placement accuracy, ensure process stability, and maintain compliance with stringent quality and reliability standards in SMT assembly operations.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-23132 aligncenter\" src=\"https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-scaled.webp\" alt=\"SMT Nozzle Cleaning Machine\" width=\"621\" height=\"586\" srcset=\"https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-scaled.webp 2560w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-300x283.webp 300w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-1024x965.webp 1024w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-768x724.webp 768w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-1536x1448.webp 1536w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-2048x1931.webp 2048w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-13x12.webp 13w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-600x566.webp 600w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-4x3.webp 4w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/11-44-10x10.webp 10w\" sizes=\"auto, (max-width: 621px) 100vw, 621px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>How the SMT Nozzle Cleaning Machine YNC-36 Is Used in Medical Electronics Factories<\/h2>\n<ul>\n<li data-start=\"144\" data-end=\"413\">\n<p data-start=\"147\" data-end=\"413\"><strong data-start=\"147\" data-end=\"207\">Maintaining Precision Placement for Sensitive Components<\/strong><br data-start=\"207\" data-end=\"210\" \/>The YNC-36 cleans SMT nozzles used to handle miniature and high-precision components such as ICs, sensors, and micro-connectors, ensuring stable vacuum performance and accurate placement on medical PCBs.<\/p>\n<\/li>\n<li data-start=\"415\" data-end=\"654\">\n<p data-start=\"418\" data-end=\"654\"><strong data-start=\"418\" data-end=\"469\">Reducing Defects in High-Reliability Production<\/strong><br data-start=\"469\" data-end=\"472\" \/>Regular nozzle cleaning minimizes placement errors, dropped components, and misalignment, supporting low-defect, high-quality assembly essential in medical electronics manufacturing.<\/p>\n<\/li>\n<li data-start=\"656\" data-end=\"894\">\n<p data-start=\"659\" data-end=\"894\"><strong data-start=\"659\" data-end=\"711\">Supporting Cleanroom and Controlled Environments<\/strong><br data-start=\"711\" data-end=\"714\" \/>The machine\u2019s controlled cleaning process is suitable for cleanroom or semi-cleanroom production lines, helping medical electronics factories maintain strict contamination control.<\/p>\n<\/li>\n<li data-start=\"896\" data-end=\"1131\">\n<p data-start=\"899\" data-end=\"1131\"><strong data-start=\"899\" data-end=\"948\">Improving Equipment Stability and Consistency<\/strong><br data-start=\"948\" data-end=\"951\" \/>By keeping nozzles in optimal condition, the SMT nozzle cleaning machine YNC-36 reduces vacuum fluctuations and mechanical stress on pick-and-place machines, ensuring stable and repeatable assembly processes.<\/p>\n<\/li>\n<li data-start=\"1133\" data-end=\"1347\">\n<p data-start=\"1136\" data-end=\"1347\"><strong data-start=\"1136\" data-end=\"1196\">Extending Nozzle Lifespan and Reducing Maintenance Costs<\/strong><br data-start=\"1196\" data-end=\"1199\" \/>Automated cleaning prevents wear caused by manual methods, prolonging nozzle life, reducing replacements, and lowering overall maintenance expenses.<\/p>\n<\/li>\n<li data-start=\"1349\" data-end=\"1559\">\n<p data-start=\"1352\" data-end=\"1559\"><strong data-start=\"1352\" data-end=\"1413\">Enhancing Compliance with Medical Manufacturing Standards<\/strong><br data-start=\"1413\" data-end=\"1416\" \/>Clean and well-maintained nozzles help factories meet ISO 13485 and other regulatory requirements, supporting traceability and audit readiness.<\/p>\n<\/li>\n<li data-start=\"1561\" data-end=\"1792\">\n<p data-start=\"1564\" data-end=\"1792\"><strong data-start=\"1564\" data-end=\"1606\">Enabling Efficient High-Mix Production<\/strong><br data-start=\"1606\" data-end=\"1609\" \/>The YNC-36 allows quick cleaning between production runs, facilitating rapid line changeovers without compromising placement accuracy or cleanliness in medical electronics assembly.<\/p>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p data-start=\"1848\" data-end=\"2130\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-23133 aligncenter\" src=\"https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2.webp\" alt=\"\" width=\"1100\" height=\"611\" srcset=\"https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2.webp 2092w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-300x167.webp 300w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-1024x569.webp 1024w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-768x427.webp 768w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-1536x853.webp 1536w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-2048x1138.webp 2048w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-18x10.webp 18w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-600x333.webp 600w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-4x3.webp 4w, https:\/\/esmte.com\/wp-content\/uploads\/2025\/12\/Nozzle2-10x6.webp 10w\" sizes=\"auto, (max-width: 1100px) 100vw, 1100px\" \/><\/p>\n<h2>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/h2>\n<table style=\"border-collapse: collapse; width: 1298px; height: 339px;\" border=\"0\" width=\"828\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Ng\u01b0\u1eddi m\u1eabu<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">YNC-24<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">YNC-36<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Cung c\u1ea5p kh\u00f4ng kh\u00ed<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">0,5~0,7 MPa<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">0,5~0,7 MPa<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Ngu\u1ed3n \u0111i\u1ec7n<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">AC220V,1A<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">AC220V,1A<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Clean liquid<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Purified water or DI water<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Purified water or DI water<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Th\u1eddi gian d\u1ecdn d\u1eb9p<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">2~3min<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">2~3min<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Th\u1eddi gian kh\u00f4<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">1~3min<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">1~3min<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Jet pressure<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">\u22640.55Mpa<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">\u22640.55Mpa<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Water consumption<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">\u2264150cc\/hour<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">\u2264150cc\/hour<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Nozzle range<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Min 01005~Max inner diameter \u00a22.0mm<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Min 01005~Max inner diameter \u00a22.0mm<\/td>\n<\/tr>\n<tr style=\"height: 30.00pt;\">\n<td class=\"et2\" style=\"height: 30pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"40\">Jig Spec<\/td>\n<td class=\"et3\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Small nozzle 24 holes<br \/>\nBig nozzle 12 holes<\/td>\n<td class=\"et3\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">Small nozzle 36 holes<br \/>\nBig nozzle 12 holes<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">K\u00edch th\u01b0\u1edbc m\u00e1y<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">L665 x W555 x H475(mm)<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">L665 x W555 x H475(mm)<\/td>\n<\/tr>\n<tr style=\"height: 15.00pt;\">\n<td class=\"et2\" style=\"height: 15pt; width: 109.5pt; text-align: center;\" width=\"146\" height=\"20\">Tr\u1ecdng l\u01b0\u1ee3ng m\u00e1y<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">40KG<\/td>\n<td class=\"et2\" style=\"width: 255.75pt; text-align: center;\" width=\"341\">40KG<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.youtube.com\/@allaismt\" rel=\"nofollow noopener\" target=\"_blank\"><u>https:\/\/www.youtube.com\/@allaismt<\/u><\/a><\/p>\n<p>For more information about the SMT Nozzle Cleaning Machine YNC-36, please send an email to<\/p>\n<p><a href=\"mailto:sophia@allaismt.com\"><u>sophia@allaismt.com<\/u><\/a><\/p>\n<p>Ch\u00fang t\u00f4i s\u1ebd ph\u1ea3n h\u1ed3i y\u00eau c\u1ea7u c\u1ee7a b\u1ea1n trong th\u1eddi gian s\u1edbm nh\u1ea5t v\u00e0 cung c\u1ea5p cho b\u1ea1n th\u00f4ng tin chi ti\u1ebft v\u1ec1 c\u00e1c s\u1ea3n ph\u1ea9m v\u00e0 d\u1ecbch v\u1ee5 c\u1ee7a ch\u00fang t\u00f4i.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>M\u00f4 t\u1ea3: C\u00e1i <strong data-start=\"177\" data-end=\"215\">M\u00e1y l\u00e0m s\u1ea1ch v\u00f2i phun SMT YNC-36<\/strong> provides an advanced, automated approach to maintaining the reliability and efficiency of SMT pick-and-place nozzles, ensuring precise handling of even the smallest components. Ideal for demanding environments such as <strong data-start=\"434\" data-end=\"467\">medical electronics factories<\/strong>, the machine prevents production interruptions by removing stubborn residues, dust, and flux buildup that can compromise nozzle suction and placement accuracy. Its gentle yet thorough cleaning process reduces wear on nozzles, lowers maintenance requirements, and supports consistent, high-quality assembly. By integrating seamlessly into SMT lines, the YNC-36 enhances overall operational efficiency, promotes stable manufacturing processes, and helps medical electronics producers meet rigorous quality and regulatory standards.<\/p>\n<p>S\u1ed1 l\u01b0\u1ee3ng \u0111\u1eb7t h\u00e0ng t\u1ed1i thi\u1ec3u: 1 chi\u1ebfc<\/p>\n<p>Th\u1eddi gian giao h\u00e0ng: 15 ng\u00e0y<\/p>","protected":false},"featured_media":23137,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"etheme_brands":[],"product_brand":[],"product_cat":[158,156],"product_tag":[],"class_list":{"0":"post-23136","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-nozzle-cleaning-machine","7":"product_cat-pcb-cleaning-machine","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product\/23136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/comments?post=23136"}],"version-history":[{"count":1,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product\/23136\/revisions"}],"predecessor-version":[{"id":23140,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product\/23136\/revisions\/23140"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/media\/23137"}],"wp:attachment":[{"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/media?parent=23136"}],"wp:term":[{"taxonomy":"brand","embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/etheme_brands?post=23136"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product_brand?post=23136"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product_cat?post=23136"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/esmte.com\/vi\/wp-json\/wp\/v2\/product_tag?post=23136"}],"curies":[{"name":"trang web","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}